Case Study Sunlight Analysis Fürstenfeldbruck

Julius Schaller · 3 min read

Case Study Sunlight Analysis · Residential project in Fürstenfeldbruck

How much sunlight actually reaches the building?

For a residential project in Fürstenfeldbruck, we simulated the duration of sunlight on the reference date of 21 March, surface by surface and including the neighbouring buildings that cast shade on it. The result is available before the design stage and shows which parts of the building can meet the requirements for habitable rooms and which cannot.

Key figures

Reference date 21 March, period 00:00 to 24:00

1,529 m²of building surface evaluated
56 %receive four or more hours of sunlight
20 %remain below one hour of direct sunlight

Starting point: building in an inner-city location means shading from the neighbours

The site lies within an established perimeter block on a main road. Together, the existing building and the extension form a courtyard. This raises a question that cannot be answered from the floor plan alone: which surfaces receive enough direct sunlight for habitable rooms to be placed there, and which do not? Neighbouring buildings, roof shapes and the self-shading of the courtyard decide this together.

Simulation of the duration of sunlight on 21 March at a residential project, coloured from yellow (many hours) to blue (under one hour)
Duration of sunlight on 21 March over the whole day. Yellow stands for nine hours or more, blue for less than one hour.

Why the neighbouring buildings must be included in the calculation

Without the shading context, sunlight hours and daylight factor come out systematically too optimistic. The values would then be reliable neither for certification nor for a design decision. We therefore also model the relevant neighbouring buildings and the terrain as shading context, georeferenced and based on our own survey.

Result: duration of sunlight by share of area

The simulation divides the evaluated building surface into classes of hours. This shows how much area has which quality, rather than discussing an average. The Forma evaluation provides ten classes, combined into five here.

Duration of sunlight on 21 March

Duration of sunlightAreaShare
under 1 hour301 m²20 %
1 to 4 hours363 m²24 %
4 to 6 hours244 m²16 %
6 to 9 hours336 m²22 %
9 hours and more285 m²18 %
Total1,529 m²100 %

For habitable rooms in dwellings, DIN 5034-1 gives a guideline value of at least four hours of sunlight on 21 March. This threshold is reached by 56 per cent of the evaluated area, while 20 per cent remains below one hour. This establishes before the design which parts of the building can accommodate habitable rooms and where ancillary rooms, circulation or building services are better placed.

Duration of sunlight in the inner courtyard: the north-facing courtyard surfaces remain below two hours
The courtyard shades itself. The north-facing courtyard surfaces remain below two hours.
Duration of sunlight seen from the south: roofs and south façades with the highest values, north sides in the lowest range
Seen from the south: roofs and south façades reach the highest values, while the north sides remain in the lowest range.

Scope: what this demonstrates and what it does not

This evaluation calculates on the building geometry, that is, on façade and roof surfaces. It answers design questions and shows the distribution across the entire project. An auditable verification under DGNB criterion SOC1.4, indicator 7, on the other hand, relates to individual rooms and requires a design model with rooms, windows and glazing parameters. Once this model is available, we run the same simulation room by room and supply room tables and a short report. The same applies to the daylight factor under DIN EN 17037, which covers indicator 1 of the same criterion.

Scope of delivery for a sunlight study

  • Colour-coded maps of the duration of sunlight per reference date, indicator 7
  • Colour-coded daylight factor maps per storey and room, indicator 1
  • Tabular evaluation per room with area, hours or daylight factor, and rating
  • Short report with methodology, reference dates and the neighbouring buildings taken into account
  • Georeferenced model of the surroundings as shading context, based on our own survey

How much sunlight reaches your site?

Tell us the address and the planned project. You will receive an assessment of which parts of the building get enough sunlight for habitable rooms.

Request a sunlight study